Cabling, interfaces, and the physical layer
Copper twisted-pair (UTP), fiber (single-mode and multi-mode), serial, and wireless. This chapter covers connector types, distance and speed limits, and how to pick the right media for the job.
Copper twisted-pair (UTP), fiber (single-mode and multi-mode), serial, and wireless. This chapter covers connector types, distance and speed limits, and how to pick the right media for the job.
Twisted-pair Ethernet uses RJ-45 connectors. Two pin-outs exist — straight-through (PC-to-switch) and crossover (switch-to-switch on legacy gear). Modern devices auto-detect with Auto-MDIX so the distinction barely matters in practice, but it is still worth knowing.
| Category | Speed | Distance | Typical use |
|---|---|---|---|
| Cat5e | 1 Gbps | 100 m | Office desks (legacy) |
| Cat6 | 10 Gbps | 55 m | Office desks (modern) |
| Cat6a | 10 Gbps | 100 m | 10G to the desktop |
| Cat7/8 | 25–40 Gbps | 30 m | Data center top-of-rack |
Multi-mode fiber (MMF) has a wider core and uses LED or VCSEL light sources. It is cheaper, easier to terminate, and is the default inside a building or data center. Distances are typically 300–550 m at 10 Gbps.
Single-mode fiber (SMF) has a much thinner core and uses laser light. It costs more but supports tens of kilometers between buildings or campuses. SMF is your only realistic option for inter-site links over a few hundred meters.
1 more section in this chapter, plus a 2-question quiz.
You can see the title, summary, and learning objectives. To read the chapter and build the labs, create a free account — Module 1 is fully readable on the free plan.
NetForge-AI is an independent educational platform and is not affiliated with, endorsed by, or sponsored by any networking vendor or certification body. All product names, protocols, and standards referenced are the property of their respective owners and are used for descriptive, educational purposes only.